Grand Vitara 2WD V6-3.2L (2010)
is out of specification, replace valve body assembly.
Pressure control solenoid and TCC pressure control solenoid resistance
Standard: 5.0 - 5.6 ohms (at 20 degrees C (68 degrees F))
Operation check
Check pressure control solenoid valves (Pressure control solenoid and TCC pressure control solenoid) (1) operation in either of the following
methods.
[Using regulated DC power supply]
1) Connect pressure control solenoid valve (1) with regulated DC power supply (2) as shown in figure.
2) Turn regulated DC power supply switch ON, increase voltage of power supply keeping current within 1.0 A.
3) Check that valve (3) moves gradually in arrow "A" direction as voltage increases.
4) Check that valve (3) moves in arrow "B" direction as voltage decreases.
5) Turn power supply switch OFF.
CAUTION:
Do not feed current 1.0 A or more, or pressure control solenoid will be burned out.