Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

Inside Air Temperature Sensor Inspection

1. Remove Inside air temperature sensor.
2. Check resistance between terminals.

Inside air temperature sensor resistance
Approx. 1.7 kohms ± 85 ohms at 25 °C (77 °F)