suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Accelerator Pedal Position (APP) Sensor Inspection|Page 2183 > < Accelerator Pedal Position Sensor|Locations|Page 2180
Page 1
background image

Accelerator Pedal Position Sensor: Testing and Inspection
Accelerator Pedal Position (APP) Sensor Inspection

APP (Accelerator Pedal Position) Sensor Inspection

1. Remove Accelerator Pedal assembly.
2. Check APP sensor output voltage as follows.

If faulty condition is found, replace accelerator pedal assembly (incorporated with APP sensor).
a. Connect 3 new 1.5 V batteries (1) in series and check that total voltage is 4.5 - 5.0 V.
b. Connect voltmeter (2) and batteries to APP sensor as shown in figure.

c. Check that voltage varies depending on accelerator opening angle as the following graph.

Accelerator Pedal Position (APP) Sensor Inspection|Page 2183 > < Accelerator Pedal Position Sensor|Locations|Page 2180