suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Positive Crankcase Ventilation Valve|Testing and Inspection|Page 2748 > < Leak Detector, Evaporative System|Locations|Page 2743
Page 1
background image

Positive Crankcase Ventilation Valve: Testing and Inspection

PCV Valve Inspection

1. Disconnect PCV valve from cylinder head cover and install plug in head cover hole.
2. Run engine at idle.
3. Place your finger over end of PCV valve (1) to check for vacuum.

If there is no vacuum, check for clogged valve. Replace PCV valve as necessary.

4. Stop engine and remove PCV valve (1).

Install clean hose to valve and check that there is air flow when blowing breath into hose from [a] to [b] and that there is no air flow when blowing
breath into hose from [b] to [a] as shown in figure.
If faulty condition is found, replace PCV valve.

Positive Crankcase Ventilation Valve|Testing and Inspection|Page 2748 > < Leak Detector, Evaporative System|Locations|Page 2743