Grand Vitara 4WD L4-2.4L (2009)
Installation
CAUTION: Proper operation of side-sensor requires that sensor is rigidly attached to specified position.
1. Check that none of following faulty conditions exists.
-
Bend, deformity or rust of under body.
-
Foreign matter on mating surface of sensor.
2. Install side-sensor (1) aligning its locating pin (2) with fitting hole (3) of under body, and tighten mounting bolt (4) to specifies torque.
Tightening torque
Side-sensor bolt (a): 11 N.m (1.1 Kg-m, 8.0 lbf-ft)