suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Starting System > < Removal and Replacement|Page 4586
Page 4
background image

Rectifier

J24B

1. Using ohmmeter, check continuity between the following terminals.

-

"B" terminal (1) and each diode lead (3)

-

"E" terminal (2) and each diode lead (3)

Check continuity in both directions by interchanging the probes.
Rectifier is normal if there is continuity only in one direction.
If there is no continuity or there is continuity in both directions, replace rectifier.