Power Door Lock Actuator: Testing and Inspection
Operation Check

Power Door Lock Actuator Circuit

1. Disconnect negative (-) cable at battery.
2. Disconnect coupler of power door lock and keyless entry controller.

3. Use a 12 V battery to connect its (+) terminal to terminal E02-1, and its (-) terminal to terminal E02-2 and E02-3. Check all power doors are

locked.

If check result is satisfactory, this circuit is OK.