Grand Vitara 4WD V6-3.2L (2010)
Air Door Actuator / Motor: Testing and Inspection
Temperature Control Actuator Inspection
Temperature Control Actuator Inspection
1. Remove temperature control actuator (1).
2. Check resistance between "d" and "e" terminals.
Temperature control actuator resistance
Max cold position: Approx. 480 ohms
Max hot position: Approx. 3.9 kohms
3. Connect using service wire, battery positive (+) terminal to terminal "b" and battery negative (-) terminal to terminal "a". Check if position of
actuator lever changes from COLD position to HOT position.
4. Connect using service wire, battery positive (+) terminal to terminal "a" and battery negative (-) terminal to terminal "b". Check if position of
actuator lever changes from HOT position to COLD position.
If malfunction is found, replace temperature control actuator with new one.