suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Headlamp Bulb|Service Precautions|Page 6996 > < Headlamp Bulb|Service Precautions|Page 6994
Page 2
background image

Fail-safe function of discharge headlight

As the ballast has a fail-safe function which stops supply of the voltage to the igniter when it detects any of the following condition.

-

Igniter is not connected to discharge headlight bulb.

-

Igniter connector is not connected to ballast.

-

Ballast detects a short or open in the circuit between discharge headlight bulb and ballast.

Headlamp Bulb|Service Precautions|Page 6996 > < Headlamp Bulb|Service Precautions|Page 6994