Grand Vitara 4WD V6-3.2L (2010)
Engine Control Module: Service Precautions
Precautions of ECM Circuit Inspection
Precautions of ECM Circuit Inspection
When measuring circuit voltage and/or pulse signal at ECM connector, connect the special tool to ECM and ECM connectors referring to Inspection of
ECM and Its Circuits:N32A See: Testing and Inspection/Pinout Values and Diagnostic Parameters and note the following.
-
ECM connectors are waterproofed. Each terminal of the ECM connectors is sealed with the grommet. Therefore, do not insert the tester probe into
sealed terminal from harness side. When measuring circuit voltage and/or pulse signal at ECM connector, be sure to connect special tool to ECM
connectors and insert tester probe into special tool's connectors at harness side. Otherwise, ECM and its circuits may be damaged by water.
-
Wire colors of special tool's connectors are different from those of ECM connectors. However, terminal arrangement of these connectors are the
same as those of ECM connectors. Therefore, be sure to identify the terminal location in order to measure proper terminal.