Starter Motor: Removal and Replacement

Starting Motor Removal and Installation

NOTE:  For identification of each cylinder and bank, refer to Precaution for Identification of Cylinder and Bank:N32A.

Removal

1. Remove bank-2 exhaust manifold.
2. Remove knock sensor.
3. Disconnect magnetic switch lead wire (1) and starting motor cable (2) from starting motor.
4. Remove starting motor mounting bolts (3).
5. Remove starting motor (4).

Installation

Reverse removal procedure noting the following.

-

Tighten starting motor mounting bolts (3) and starting motor cable nut (5) to specified torques.

Tightening torque

Starting motor cable nut (a): 11 N.m (1.1 kg-m, 8.5 lbf-ft)
Starting motor mounting bolt (b): 45 N.m (4.6 kg-m, 33.5 lbf-ft)