Grand Vitara 4WD V6-3.2L (2010)
Fluid - Transfer Case: Testing and Inspection
Transfer With Shift Actuator
Transfer Oil Level Check
1) Lift up vehicle and check oil leakage.
2) Remove oil level/filler plug (1) and check oil level is between 0 and 10 mm (0 and 0.394 in.) from the lower end of oil level / filler plug hole (2).
If oil is insufficient, pour specified oil up to plug hole.
3) Apply sealant to thread of level / filler plug, and then tighten it to specified torque.
"A": Sealant 99000-31260 (SUZUKI Bond No.1217G)
Tightening torque
Transfer oil level / filler plug (a): 23 Nm (2.3 kg-m, 17.0 lbf-ft)