Condenser HVAC: Testing and Inspection

CONDENSER ASSEMBLY INSPECTION

Check a) condenser fins for blockage, b) condenser fittings for leakage, and c) condenser fins for damage.

Clogged condenser fins should be washed with water, and should be dried with compressed air.

NOTE:  Be careful not to damage condenser fins. If condenser fin is bent, straighten it by using a screwdriver or pair of pliers. If any leakage is found
from fitting or tube, repair or replace condenser.