suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Control Assembly, HVAC|Testing and Inspection|Page 3320 > < Condenser Fan Motor Relay, HVAC|Locations
Page 1
background image

Control Assembly: Testing and Inspection

HEATER MODE CONTROL SWITCH INSPECTION

Mode Control Switch

-

Check if continuity exists between each pair of terminals listed when mode control button is pressed.

-

With battery voltage (+) connected to terminal "I" and (-) to terminal "F", press each mode control button and check if indicator lamp lights.

-

With battery voltage (+) connected to terminal "A" and (-) to terminal "H", check if illumination lamp lights.

A/C Switch (if equipped)

-

Press A/C button and check if there is continuity between terminals "D" and "G".

-

With battery voltage (+) connected to terminal "K" and (-) to terminal "D", press A/C button and check if indicator lamp lights.