Blower Motor Relay: Testing and Inspection

HEATER BLOWER RELAY INSPECTION

1. Connect battery positive (+) terminal to terminal "2" of relay.
2. Connect battery negative (-) terminal to terminal "1" of relay.
3. Check continuity between terminal "3" and "4".

If there is no continuity when relay is connected to the battery, replace relay.