Variable Induction Control Actuator: Initial Inspection and Diagnostic Overview
IMT Valve Actuator Inspection
CAUTION: Be sure not to apply battery voltage to IMT valve actuator for 10 seconds or more.
Connect battery positive (+) and negative (-) terminals to IMT valve actuator (2) as shown in table below. If IMT valve actuator pinion gear (1) does not
operate as specified direction, replace IMT valve actuator.
IMT valve actuator pinion gear rotative direction