Blower Motor: Service and Repair

Blower Motor Removal and Installation

Removal

1. Disconnect the negative battery cable.
2. Remove the glove box.
3. Put the floor carpet aside for preventing stain.
4. Disconnect the blower motor electrical connector and resistor connector.

5. Remove the screws that secure the motor to the heater/air distributor case.

6. Remove the motor, the seal, and the shock mount pads from the heater/air distributor case by gently pulling the motor straight down and out.

Installation

1. Install the blower motor and the seal with the shock mount pads in the heater/air distributor case. Hold the blower motor in position.
2. Install the screws to secure the blower motor to the heater/air distributor case.

Tighten: Tighten the blower motor retaining screws to 1.2 Nm (11 in. lbs.).

3. Connect the blower motor electrical connector and resistor connector.
4. Connect the negative battery cable.
5. Confirm that the blower motor operates properly.

6. Install the glove box.