Alternator: Testing and Inspection
Generator System Check

Generator System Check

When operating normally, the generator indicator lamp will come on when the ignition is in RUN position and go out when the engine starts. If the lamp
operates abnormally or if an undercharged or overcharged battery condition occurs, the following procedure may be used to diagnose the charging
system. Remember that an undercharged battery is often caused by accessories being left on overnight or by a defective switch that allows a lamp, such
as a trunk or a glove box lamp, to stay on.

Diagnose the generator with the following procedure:

1. Visually check the belt and the wiring. 
2. With the ignition in the ON position and the engine stopped, the charge indicator lamp should be on. If not, detach the harness at the generator and

ground the "L" terminal in the harness with a 5-ampere jumper lead. 
^

If the lamp lights, replace the generator. Refer to Generator Removal and Installation.

^

If the lamp does not light, locate the open circuit between the ignition switch and the harness connector. The indicator lamp bulb may be
burned out. 

3. With the ignition switch in the ON position and the engine running at moderate speed, the charge indicator lamp should be off. If not, detach the

wiring harness at the generator. 
^

If the lamp goes off, replace the generator. Refer to Generator Removal and Installtion.

^

If the lamp stays on, check for a short to ground in the harness between the connector and the indicator lamp.

Alternator|Service and Repair > < Generator Output Test