Valve Guide: Service and Repair

Fig. 10 Removing valve guides

1.

Using valve guide removal tool 09916-44511, or equivalent, remove valve guides as shown in Fig. 10. Do not reuse valve guides after removal.

2.

Using a suitable micrometer and bore gauge, measure diameter of valve stem and valve guide inside diameter, to determine stem clearance in
guide.

3.

Clearances should be as follows:

a. Intake valve stem diameter should be 0.2742-0.2748 inch (6.965-6.980 mm) and exhaust valve stem diameter 0.2737-0.2742 inch

(6.950-6.965 mm).

b. Valve guide inside diameter should be 0.2756-0.2761 inch (7.000-7.015 mm).
c. Stem to guide clearance should be, intake; 0.0008--0.0019 inch (0.020-0.050 mm): exhaust; 0.0014-0.0025 inch (0.035-0.065 mm).

Fig. 11 Checking valve stem end deflection

4.

If bore gauge is not available, check valve stem end deflection using a suitable dial indicator as shown in Fig. 11. Move stem end back and forth, 
Fig. 11, and measure valve stem end deflection.

5.

Valve stem end deflection should be as follows:

a. Intake, 0.005 inch (0.14 mm).
b. Exhaust, 0.007 inch (0.18 mm).

6.

If specifications are not as specified, replace valve and guide as necessary. 

Valve Seat > < Valve Cover|Specifications