suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Exhaust Gas Recirculation > < Evaporative Emission Control Canister|Description and Operation|Page 935
Page 4
background image

Fig. 3 Vapor storage canister cross sectional view

VAPOR STORAGE CANISTER
    Take care not to inhale fuel vapor inside canister.

1.

Disconnect battery ground cable.

2.

Disconnect hoses from canister, then remove canister.

3.

Hold pipes C and D closed with fingers, Fig. 3, then blow air into pipe A. Air should come out from pipe B, if not, replace canister.

4.

Blow air into pipe B, air should not pass through pipes A, C or D, if not, replace canister

5.

Blow air into pipe C, air should come out from pipes A, B and D, if not, replace canister.

6.

Install canister, connect hoses and battery ground cable.

Exhaust Gas Recirculation > < Evaporative Emission Control Canister|Description and Operation|Page 935