Sidekick 2WD L4-1590cc 1.6L SOHC 0 TBI 8V (1992)
Step 4:
Align seal with end of cable insulation (Weather Pack(R) terminals only).
Step 5:
Position strip (and seal for Weather Pack(R)) in terminal.
Step 6:
Hand crimp core wings.
Step 7:
Hand crimp insulation wings (non-Weather Pack(R)). Hand crimp insulation wings around seal and cable (Weather Pack(R)).
Step 8:
Solder all hand crimped terminals.
Typical Electrical Repair
TYPICAL ELECTRICAL REPAIR
An open circuit is an incomplete circuit. Power cannot reach the load or reach ground. If a circuit is open, active components do not energize. A
short circuit is an unwanted connection between one part of the circuit and either ground or another part of the circuit. A short circuit causes a fuse
to blow or a circuit breaker to open.
SHORT CIRCUITS CAUSED BY DAMAGED WIRE INSULATION
^
Locate the damaged wire.
^
Find and correct the cause of the wire insulation damage.
^
For minor damage, tape over the wire. If damage is more extensive, replace the faulty segment of the wire.