Torque Converter Clutch Relay: Description and Operation

Lock-Up Relay Circuit

This system control lock-up of the A/T torque convertor.
The lock-up solenoid, under control from the  stop light switch, A/T oil pressure switch and lock-up relay, opens and closes the oil passage to lock and
unlock the torque convertor.

Lock-Up Relay ON Zone

The factors which the ECM uses to control the lock-up relay are the signals from the throttle position sensor (throttle plate angle), ignitor (engine rpm)
and engine coolant temperature. It energizes the solenoid only during a certain throttle valve opening angle (shaded area in illustration) and only when
the engine temperature is 60° C (140° F) or higher.

Battery voltage is supplied to the solenoid only when the relay is energized, the brake pedal is released and the A/T oil pressure is higher than a specific
point (A/T pressure switch is ON).

Even when the lock-up relay is ON, if the brake pedal is pressed or the A/T oil pressure is low, the lock-up circuit opens and no voltage is applied.