Step 4:

Align seal with end of cable insulation (Weather Pack(R) terminals only).

Step 5:

Position strip (and seal for Weather Pack(R)) in terminal.

Step 6:

Hand crimp core wings.

Step 7:

Hand crimp insulation wings (non-Weather Pack(R)). Hand crimp insulation wings around seal and cable (Weather Pack(R)).

Step 8:

Solder all hand crimped terminals.

Typical Electrical Repair

TYPICAL ELECTRICAL REPAIR

An open circuit is an incomplete circuit. Power cannot reach the load or reach ground. If a circuit is open, active components do not energize. A
short circuit is an unwanted connection between one part of the circuit and either ground or another part of the circuit. A short circuit causes a fuse
to blow or a circuit breaker to open.

SHORT CIRCUITS CAUSED BY DAMAGED WIRE INSULATION

^

Locate the damaged wire.

^

Find and correct the cause of the wire insulation damage.

^

For minor damage, tape over the wire. If damage is more extensive, replace the faulty segment of the wire.