suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Heated Oxygen Sensor 1|Page 1494 > < Heated Oxygen (HO2S) Sensor|Page 1491
Page 1
background image

Oxygen Sensor: Service and Repair
Heated Oxygen Sensor 1

Removal 

WARNING:
To avoid danger of being burned, do not touch exhaust system when system is hot. Oxygen sensor removal should be performed when
system is cool.
 

1) Disconnect negative cable from battery.
2) Disconnect coupler of oxygen sensor.
3) Remove exhaust manifold upper cover.

4) Remove oxygen sensor from exhaust manifold.

NOTE: Be careful not to expose it to excessive shock.

Installation 
Reverse removal procedure noting the following.

-

Tighten oxygen sensor to specified torque.

Tightening Torque
(a): 43 N m (4.3 kg-m, 31.5 lb-ft)
 

-

Connect coupler of oxygen sensor and clamp wire harness securely.

-

After installing oxygen sensor, start engine and check that no exhaust gas leakage exists.

Heated Oxygen Sensor 1|Page 1494 > < Heated Oxygen (HO2S) Sensor|Page 1491