Canister Purge Solenoid: Testing and Inspection
Using Suzuki Scan Tool

1) Disconnect vacuum hoses from intake manifold and EVAP canister.

2) With ignition switch ON, blow into hose "A". Air should not come out of hose "B". 

3) Connect SUZUKI scan tool to DLC with ignition switch OFF.

-

Turn ON EVAP canister purge valve by using SUZUKI scan tool with ignition switch ON.

-

In this state, blow hose "A".

-

Air should come out of hose "B".

WARNING:
Do not suck the air through valve. Fuel vapor inside valve is harmful.
 

If check results are as described above, EVAP canister purge valve and its circuit are in good condition, connect vacuum hoses securely.
If not, proceed to step 4).

4) With ignition switch OFF, disconnect coupler from EVAP canister purge valve.
5) Check resistance between two terminals of EVAP canister purge valve.

Resistance of EVAP canister purge valve:

Using Suzuki Scan Tool|Page 1561 > < Canister Purge Solenoid|Specifications