suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 1906 > < Hydraulic Control Assembly - Antilock Brakes|Specifications|Page 1903
Page 1
background image

Hydraulic Control Assembly - Antilock Brakes: Initial Inspection and Diagnostic Overview

Hydraulic Unit Inspection

-

Check hydraulic unit for fluid leakage. If any, repair or replace.

Pump Motor Inspection

1) Turn ignition switch "OFF". 
2) Disconnect motor connector. 
3) Check motor for resistance.

Between motor terminals: Less than 1 ohms at 20°C (68°F)
Between terminal and motor body:  1 M ohms or more
 

4) Connect 12V battery positive terminal to motor connector terminal "1 " and negative terminal to "2". Then check if operation sound is heard from

motor. If faulty condition was found in Steps 3 or 4, replace hydraulic unit.

Solenoid Valve Inspection