Swift L4-1298cc 1.3L SOHC MFI (1997)
Ignitor: Testing and Inspection
Before this check, prepare 2 new 1.5V batteries and an analog type ohmmeter.
1. Remove power unit from its bracket.
2. Arrange 2 new 1.5V batteries in series (check that total voltage is about 3.0 V). Connect positive terminal of ohmmeter to "G" terminal of
power unit and negative terminal to "0C" terminal. Check continuity between "G" and "0C" terminals with about 3V voltage applied to its "IB"
terminal and also none applied.
No voltage applied to "IB" terminal: No continuity (infinity)
Voltage applied to "IB" terminal: Continuity
If check result is not satisfactory, replace power unit.
3. Install power unit.