BRUSH AND BRUSH HOLDER 

Check each brush for wear by measuring its length as shown.
If brush is found worn down to service limit,replace brush.

Brush length A
Standard: 16 mm (0.63 in.) 
Limit   : 2 mm (0.06 in.)
 

RECTIFIER 

1) Using ohmmeter,check continuity between each of upper and lower rectifier bodies and each diode lead as shown.Check both directions by

reversing probes of ohmmeter and there should be only one-way continuity in each case.If check result is not satisfactory, replace rectifier.

2) In the same manner as described in above step 1),check that there is only one-way continuity between both leads of diode trio.