Swift GL L4-1298cc 1.3L SOHC MFI (2000)
-
Ground Test
Check for continuity between brush and bare surface. If there is continuity, field windings are grounded. The yoke must be replaced.
3. BRUSH
Check brushes for wear. If below limit, replace brush.
Brush length
Standard : 17 mm (0.67 in.)
Limit : 11.5 mm (0.45 in.)
4. BRUSH HOLDER AND SPRING
-
Check movement of brush in brush holder. If brush movement within brush holder is sluggish, check brush holder for distortion and sliding
faces for contamination.
Clean or correct as necessary.
Check for continuity across insulated brush holder (positive side) and grounded brush holder (negative side).
If continuity exists, brush holder is grounded due to defective insulation and should be replaced.