suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

HVAC - Air Conditioning System|Page 4760 > < HVAC - Air Conditioning System
Page 2
background image

1. Remove air flow control actuator from HVAC unit referring to Air Flow Control Actuator Removal and Installation:Automatic Type.
2. Connect connector to air flow control actuator.
3. Set air flow selector to "BENT" position with ignition switch turned ON.
4. Connect voltage meter between terminal "2" and body ground.
5. Turn air flow selector to "DEF" position.
6. Measure output voltage variation while air flow control actuator is operated from "BENT" position (A) to "DEF"  position (B) as following

specification.