CAUTION:  Adjust the pressure regulator carefully. Turning the regulator plunger too far clockwise will cause the plunger to lock
up, turning the regulator plunger too far counter clockwise will cause the plunger and spring to fall out of the regulator.

c. Use a flat-blade screwdriver to adjust the regulator plunger until the pressure/vacuum gauge reads 13 in. H2O pressure.
d. Disconnect and reconnect the nitrogen/smoke hose from the self-test port.
e. Press and release the remote switch.
f.

Verify pressure is at 13 in. H2O. If not, repeat Steps b) to f), as necessary.

g. Press and release the remote switch to deactivate the tester.
h. Replace the plastic cap on the regulator, and then disconnect the nitrogen/smoke hose from the self-test port.

Pressurization Test