EVAP Leak Check Pressure Sensor (combine with BARO sensor) check

Reference: EVAP Leak Check Module Removal and Installation
Check barometric pressure and reference vacuum pressure as follows.

1. Initial (barometric) pressure check:

a. Arrange 3 new 1.5 V batteries (1) in series and connect its positive terminal to terminal 4 for EVAP leak check pressure sensor of EVAP leak

check module and negative terminal "2".

b. Check EVAP leak check pressure sensor output voltage (barometric pressure signal voltage) between terminal "3" and "Ground" terminal.

If output voltage is out of specification, replace EVAP leak check module.
If output voltage is within specified value, go to next step.

CAUTION:  Check to make sure that connection is made between correct terminals. Wrong connection can cause damage to EVAP
leak check pressure sensor in EVAP leak check module.

EVAP leak check pressure sensor output voltage for initial (barometric) pressure (Terminal "4" voltage 4.5 - 5.5 V, ambient temp. 20 - 30 °C
(68 - 86 °F))

2. Reference vacuum pressure (reference orifice vacuum) check:

EVAP Leak Check System Leak Inspection|Page 2420 > < EVAP Leak Check System Leak Inspection|Page 2418