suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Variable Induction Control Actuator|Testing and Inspection|Page 2605 > < Variable Induction Control Actuator|Testing and Inspection
Page 1
background image

Variable Induction Control Actuator: Service and Repair

IMT Valve Actuator Removal and Installation 

Removal 

1. Disconnect negative (-) cable at battery.
2. Disconnect IMT valve actuator connector.
3. Remove IMT valve actuator (1) and O-ring (2) from intake manifold (3).

Installation 

Reverse removal procedure noting the followings.
^

Use new O-ring (1).

^

Tighten IMT valve actuator bolt (2) to specified torque.

Tightening torque

IMT valve actuator bolt a: 6 Nm (0.6 kgf-m, 4.5 ft. lbs.) 

Variable Induction Control Actuator|Testing and Inspection|Page 2605 > < Variable Induction Control Actuator|Testing and Inspection