suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Air Door Cable, HVAC|Service and Repair|Page 3131 > < Diagram Information and Instructions|Page 3126
Page 1
background image

Air Door Cable: Service and Repair

Temperature Cable Removal and Installation

NOTE:

-

Because the cable and the cable housings have fixed lengths, it is impossible to make a temperature cable adjustment.

-

Remove the glove box.

-

If a malfunction is suspected, verify the proper operation of the controller and the mechanical doors for the heater/air distributor case assembly.

Removal

1. Disconnect the negative battery cable.
2. The heater/air distribution case linkage also cannot be adjusted.
3. Disconnect the cable retainer from the blower housing.

4. Slide the cable eyelet off the post on the temperature door lever.
5. Remove the audio system trim plate. Refer to Instrument Cluster Trim Panel Removal.
6. Remove the four controller retaining screws.
7. Pull out the controller to provide clearance for removal of the temperature control cable.
8. Disconnect the temperature control cable eyelet from the post on the controller.

9. Snap the cable housing connector out of the slide position on the controller.

Installation

1. Install the temperature control cable eyelet to the post on the controller.

Air Door Cable, HVAC|Service and Repair|Page 3131 > < Diagram Information and Instructions|Page 3126