suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Blower Motor Resistor > < Diagram Information and Instructions|Page 3149
Page 1
background image

Blower Motor Relay: Service and Repair

High-Blower Relay Removal and Installation

High-Blower Relay Removal

1. Disconnect the negative battery cable.
2. The relay is located in front of the blower motor.
3. Remove the glove box lower panel cover. Refer to Glove Box Removal.
4. Separate the relay from the connector.

5. Remove the screws with the high-blower relay.

High-Blower Relay Installation

1. Install the screws with the high blower relay.
2. Connect the electrical connector.

3. Install the glove box lower panel cover. Refer to Glove Box Installation.

Blower Motor Resistor > < Diagram Information and Instructions|Page 3149