Verona L6-2.5L (2005)
Refrigerant Pressure Sensor / Switch: Service and Repair
A/C Pressure Transducer Removal and Installation
A/C Pressure Transducer Removal
1. Disconnect the negative battery cable.
2. Release the connector lock and pull the transducer wire connector out.
3. Remove the transducer with a wrench.
4. Discard the O-ring seal.
A/C Pressure Transducer Installation
1. Install the new O-ring seal on the transducer.
2. Install the pressure transducer.
Tighten:
Tighten the pressure transducer to 7 N.m (62 lb.in).
3. Connect the wire connector.