8. Test the rectifier bridge by connecting the ohmmeter terminals to the bridge and the heat sink.

9. Retest by connecting the ohmmeter terminals in reverse.

10. Replace the rectifier bridge, if each reading is the same.
11. Test the remaining two diodes after the above procedure.

12. Test the diodes by connecting the ohmmeter terminals to the bridge terminal and the base plate. If the reading is the same, the rectifier bridge

should be replaced.

NOTE:  Some kinds of digital ohmmeters are not suited for the test of the bridge diode. In this case, consult the manufacturer regarding the test
capacity.