Valve Clearance: Specifications

 

Valve clearance specifications

Intake

When cold

0.13 - 0.17 mm 

(Coolant temperature is 15 - 25 deg C (59 - 77 deg. F))

 

   

  

  

  

 

When hot

0.17 - 0.21 mm 

(Coolant temperature is 60 - 68 deg C (150 - 154 deg F))

 

    

 

   

  

  

 

Exhaust When cold

0.23 - 0.27 mm 

(Coolant temperature is 15 - 25 deg C (59 - 77 deg. F))

 

    

 

  

  

  

 

When hot

0.28 - 0.32 mm 

(Coolant temperature is 60 - 68 deg C (150 - 154 deg F))

 

    

 

    

  

  

 

Valve stem to guide clearance

IN

Standard

0.020 - 0.047 mm 

   

  

  

  

 

Limit

0.07 mm 

    

  

 

     

  

  

 

EX

Standard

0.045 - 0.072 mm 

    

  

 

  

  

  

 

Limit

0.09 mm 

    

  

 

      

  

  

 