Vitara 4WD L4-2.0L (2003)
Blower Motor Relay: Testing and Inspection
Blower Motor Relay Inspection
1. Connect battery positive (+) terminal to terminal (1) of relay.
2. Connect battery negative (-) terminal to terminal (2) of relay.
3. Check continuity between terminal (3) and (4).
If there is no continuity, replace relay.