suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Actuator, Differential Lock > < Air Pump, Differential Lock|Testing and Inspection
Page 1
background image

Air Pump: Service and Repair

Removal and Installation 

1) Disconnect air hoses and coupler from air pump assembly.
2) Remove pump assembly by removing bolts.
3) Before installation, inspect air leakage and voltage.

4) Reverse removal procedure for installation.

Inspection 

1) Install special tool, voltmeter and battery to pump assembly (1) as shown in figure.

2) Tighten adjusting screw of special tool as far as it stops and close its air check side opening by using fuel hose as blind plug.
3) Check that motor starts to run (a sound can be heard) when battery is connected and it stops when specified pressure is obtained. Check also for air

leakage.
Air pressure specification (for stopping motor) 30.0 - 45.0 kPa (0.30 - 0.45 kgf/cm2, 4.25 - 6.40 psi) 

4) Check that value indicated on voltmeter is within specification shown below.

Air pump assembly motor specification

When motor is running: 0 - 1 V 
When motor has stopped running: 10 - 14 V 

CAUTION:   Do not run motor more than 10 seconds continuously to prevent motor breakage.

Actuator, Differential Lock > < Air Pump, Differential Lock|Testing and Inspection