2. Connect inner end (5) of interlock cable to key interlock lever (4) (Ignition switch side).
3. Install outer end bracket (3) of interlock cable to ignition switch assembly (1), and tighten screw (2) to specified torque.

Tightening torque

Interlock cable clamp screw (a): 2.2 Nm (0.22 kg-m, 1.5 ft. lbs.) 

4. Pass and connect interlock cable (1) as shown in the figure.

5. For type-1

a. Fix interlock cam (1) by inserting pin (4) with about 4 mm (0. 15 inch) dia. into holes of cam (1) and lever plate (2).
b. Install cable end to interlock cam (1) and stud bolt and after making sure that cable outer (3) is pushed in arrow direction B by leaf spring,

tighten mounting nut to specified torque. Remove pin (1).
Tightening torque
Interlock cable outer mounting nut (a) 13 Nm (1.3 kg-m, 9.5 ft. lbs.) 

c. Turn ignition key to "ACC" position and shift select lever to "N" range, and check for the followings.
i.

When select lever is shifted at "P" range with knob button depressed, ignition key can not be turned from "ACC" to "LOCK" position.

ii. When knob button is released, ignition key can be turned to "LOCK" position.
iii. When ignition key is at "LOCK" position, select lever can not be shifted from "P" to any other range.
d. Install console box.
e. Install steering column cover.
f.

Adjust steering column or tighten steering column bolts.

g. Install steering column hole cover.
h. If equipped with air bag system, enable air bag system.

6. For type-2