background image

Generator itself has problem, check the generator.

Load Check [85 A type only]

1. Run engine at 2,000 rpm and turn on head light and heater motor.
2. Measure current and if it is less than 30 A repair or replace generator.

Overcharged Battery

1. To determine battery condition, refer to BATTERY.
2. If obvious overcharge condition exists as evidenced by excessive spewing of electrolyte, measure generator B terminal voltage at engine 2000 rpm

.

3. If measured voltage is higher than upper limit value, proceed to disassembly of generator service.
4. Check ground of brushes. If brushes are not grounded, replace IC regulator. Then check field coil for grounds and shorts.