1. Shift select lever to "N" range and turn ignition key to "ACC" position.
2. Connect inner end of interlock cable to key interlock lever (Ignition switch side).
3. Install outer end bracket of interlock cable to ignition switch assembly, and tighten screw to specified torque.

Tightening Torque
(a): 2.2 Nm (0.22 kg.m, 1.5 ft. lbs.) 

4. Pass and connect interlock cable as shown in the figure.

TYPE-1 

5. Fix interlock cam by inserting pin with about 4 mm (0. 15 inch) dia. into holes of cam and lever plate.
6. Install cable end to interlock cam and stud bolt and after making sure that cable outer is pushed in arrow direction B by leaf spring, tighten

mounting nut to specified torque. Remove pin.
Tightening Torque
(a): 13 Nm (1.3 kg.m, 9.5 ft. lbs.) 

7. Turn ignition key to "ACC" position and shift select lever to "N" range, and check for the followings.

a. When select lever is shifted at "P" range with knob button depressed, ignition key can not be turned from "ACC" to "LOCK" position.
b. When knob button is released, ignition key can be turned to "LOCK" position.
c. When ignition key is at "LOCK" position, select lever can not be shifted from "P" to any other range.

8. Install console box.