suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Control Assembly, HVAC|Service and Repair > < Condenser Fan Motor Relay, HVAC|Locations|Page 3234
Page 1
background image

Control Assembly: Testing and Inspection

Mode control switch specification:

-

Check if continuity exists between each pair of terminals listed when mode control button is pressed.

-

With battery voltage (+) connected to terminal "I" and (-) to terminal "F", press each mode control button and check if indicator lamp (3) lights.

-

With battery voltage (+) connected to terminal "A" and (-) to terminal "H", check if illumination lamp lights.

Control Assembly, HVAC|Service and Repair > < Condenser Fan Motor Relay, HVAC|Locations|Page 3234