11. Remove generator belt idler pulley.
12. Disconnect radiator outlet hose from thermostat cap.
13. With hoses connected, detach A/C compressor from compressor bracket if equipped.
14. Remove A/C compressor bracket if equipped.

15. Remove crankshaft pulley bolt.

To lock crankshaft pulley, use special tool (camshaft pulley holder) with it as shown in figure.
Special Tool

(A): 09917-68221

NOTE:  Be sure to use the following bolt for fixing special tool to crankshaft pulley. 
Bolt size: M8, P1.25 l = 45 mm
Strength: 7T

16. Remove crankshaft pulley.

If it is hard to remove, use special tools (Steering wheel remover and Bearing puller attachment) as shown in figure.
If bolts of steering wheel remover are too long, replace them with those of suitable length.
Special Tools

(A): 09944-36011
(B): 09926-58010

17. Remove timing chain cover.

CLEAN

^

Clean sealing surface on timing chain cover, crankcase, cylinder block and cylinder head. 
Remove oil, old sealant, and dust from sealing surface.

INSPECTION

^

Check oil seal lip for fault or other damage. Replace as necessary.

Sealant Application Area|Page 1026 > < Sealant Application Area|Page 1024