Reverse removal sequence to install condenser dryer, according to instruction manual with supply parts.

NOTE:

^

When replacing condenser dryer, add 40 cc of refrigerating oil the same as compressor oil.

^

Do not remove the dryer from the plastic bag until just before inserting it into the receiver.

^

Install the condenser dryer with its double-layer portion facing the bottom of the receiver.

Cap Tightening Torque
:

12.5 ± 2.5 Nm

:

1.25 ± 0.25 kg.m 

:

9 ± 1.8 ft. lbs.