background image

Stator

^

Using ohmmeter, check all leads for continuity. If there is no continuity, replace stator.

^

Using ohmmeter, check that there is no continuity between coil leads and stator core. If there is continuity, replace stator.

Brush and brush holder

Check each brush for wear by measuring its length as shown. If brush is found worn down to service limit, replace brush.

Exposed brush length "a"
Standard: 10.5 mm (0.413 in)

Limit : 4.5 mm (0.351 in)

Rectifier