Vitara JX (2Dr) 4WD L4-16L DOHC MFI (1999) - Expansion Valve Component Location
Expansion Valve: Service and Repair
EXPANSION VALVE
REMOVAL
1. Recover refrigerant by using recovery and recycling equipment. Be sure to follow the instruction manual for the equipment. The amount of
compressor oil removed must be measured and the same amount added to the system.
2. Remove front grill.
3. Disconnect suction pipe, and liquid pipe from evaporator (Cooling unit).
NOTE: As soon as above hose and pipe are disconnected, cap opened fittings so that moisture and dust may not enter cooling Unit.
4. Disconnect suction pipe, and liquid pipe from suction hose and condenser outlet pipe.
5. Remove pipe clamp then remove suction pipe and liquid pipe.
6. Remove expansion valve.
INSTALLATION
1. Reverse removal sequence to install expansion valve.
2. Evacuate and charge system according to previously described procedure.