Valve Clearance: Specifications
CLEARANCE

CLEARANCE
 

Intake

When Cold

0.13 - 0.17 mm 

Temperature is 15 - 25 deg C

 

      

  

  

 

When Hot

0.17 - 0.21 mm 

Temperature is 60 - 68 deg C

 

       

  

  

 

Exhaust When Cold

0.23 - 0.27 mm 

Temperature is 15 - 25 deg C

 

      

  

  

 

When Hot

0.28 - 0.32 mm 

Temperature is 60 - 68 deg C

 

        

  

  

 