Vitara JX (2Dr) 4WD L4-1.6L DOHC MFI (1999)
Wiper Relay: Testing and Inspection
1. Disconnect negative cable at battery.
2. Disconnect combination switch lead wire coupler.
3. Turn the front wiper switch to INT position.
4. Turn the intermittent time control switch to FAST position.
5. Connect battery positive terminal to terminal "B3" and battery negative terminal to terminal "E".
6. Connect voltmeter positive lead to terminal "+1" and negative lead to terminal "E".
Check that the voltmeter indicates the battery voltage (10 - 14 V).